> labs for EMC tests  
EMC Testing facilities

Semi-anechoic chamber 3 m/40 GHz
Test chamber
actual size 11 x 7,5 x 4,5 m
main door 4 x 4 m
anechoic absorbers
 - ceiling ferrite/absorbers elements
(5 and 50 cm long)
 - walls ferrite/absorbers elements
(50 and 200 cm long)
electric field attenuation > 100 dB up to 40 GHz
magnetic field attenuation > 65 dB up to 1 MHz
Normalized Site Attenuation < ± 4 dB in respect of theoretic one from 30 MHz to 1 GHz
field uniformity < 6 dB dB in complete compliance with standards EN 61000-4-3 and
IEC 1000-4-3
antenna type automatic for measurements of between 1 and 4 m with horizontal and vertical polarisation.
turntable
 - diameter 2 m
 - max. loading capability 1000 kg
emissions measuring system automatic
immunity testing system automatic
Shielded control chamber
actual size 10 x 5 x 3 m
electric field attenuation > 100 dB to 10 GHz
magnetic field attenuation > 52 dB to 1 MHz
General utilities
Power outlets
(100 dB from 14 kHz to 10 GHz)
220 V single-phase - 50 Hz - 22 kVA
380 V three-phase - 50 Hz - 66 kVA
115/208 V three-phase - 400 Hz - 40 kVA
0 ÷ 160 V d.c. - 25 kW
3 TVCC systems with pan/zoom/tilt
Intercommunication system
Air conditioning in test and control chambers
Smoke and/or discharge gas elimination system
Fire detection and extinguishing system
Semi-anechoic chamber 10 m
Test Chamber
Dimensions 23 x 16 x 12 m
Working height 9,5 m
Main access door 3,7 x 4,2 m
Floor loading
capability
2.500 ÷ 5.000
kg/m2
Absorbers

- (walls and ceiling) 244 cm long
- arrangement for absorber
  installation under the floor
General services
Electric field attenuation > 105 dB up to 10 GHz
Magnetic field attenuation: > 74 dB up to 1 MHz
Normalized Site Attenuation < ± 4 dB in respect with the theoretic one from 30 MHz to 1 GHz
Field uniformity: 0 ÷ 6 dB from 20 MHz to 1 GHz
Turntable diameter: 7.3 m
loading capability: > 15 t
control: manual/automatic
Rolls (for vehicles)

length 850 mm
gauge 700 mm ÷ 2,400 mm
maximum load 5,000 kg
adjustable wheelbase 1,300 ÷ 2,750 mm
roll distance 400 ÷ 600 mm
arrangement for installation of another rolls set
Monitoring and control systems

* 8-channel optic fibre transmission system:
   frequency range dc ÷ 100 kHz; maximum input voltage: 100 V
* Electro-pneumatic control system:
   - n.3 channels for control of brakes, accelerator and clutch
   - n.6 on/off command channels
* System for ABS operation verification.
Antenna system and turntable computer controlled
Services and Control Shielded Chambers
Dimensions

Control chamber 5 x 5 x 3 m
Client apparatus storage chamber 5 x 4.5 x 3.0 m
Amplifier chamber 5 x 3.5 x 3.0 m
Electric field attenuation > 105 dB up to 10 GHz
Magnetic field attenuation > 78 dB up to 1 MHz
General
Utilities
* Power outlets (> 105 dB filtered from 14 kHz to 10 GHz)
- 220 V single-phase - 50 Hz - 22 kVA
- 380 V three-phase - 50 Hz - 66 kVA
- 115/208 V three-phase - 400 Hz - 40 kVA
- 0 ÷ 160 V - d.c. 25 kW
* 3 TVCC systems with pan/zoom/tilt
* Intercommunication system
* Air conditioning in test, service and control chambers
* Smoke and/or discharge gas elimination system
Industrial Shielded Chambers

n.1
Dimensions 8 x 6 x 3 m
Main access door 2 x 2.50 m
Floor load capability 5.000 kg/m²
Electric field attenuation >120 dB up to 10 GHz
Magnetic field attenuation >60 dB up to 1 MHz

n.2
Dimensions 10.7 x 5 x 3 m
Main access door 2 x 2.80 m
Floor load capability 2,000 kg/m²
Electric field attenuation >120 dB up to 10 GHz
Magnetic field attenuation >70 dB up to 1 MHz

n.3
Dimensions 5 x 5 x 3 m
Main access door 2 x 2.80 m
Floor load capability 2,000 kg/m²
Electric field attenuation >120 dB up to 10 GHz
Magnetic field attenuation >70 dB up to 1 MHz
SIRF Rilevamento fulmini
Cesi Meteo
Contact us
Site map

Search
 
Italiano